omreport: Viewing System Status Using the Instrumentation Service 65
---------------
Power Supplies
----------------
Settings
Enable: Informational, Warning and Critical
Disable: None
-----------
Fans
-----------
Settings
Enable: Critical
Disable: Informational and Warning
The full report lists the settings for all components in your system for which
events can be generated.
To view the status for components of a specific type, use the omreport system
events type=<component name> or omreport servermodule event type=
<component name> command. This command displays a summary of each
component in your system for which events can be generated. Table 3-7
shows the events displayed for various component types.
NOTE: Due to the limitations of certain operating systems (for example, VMware
®
ESXi), certain features may not be available with this release of OpenManage
Server Administrator.
Table 3-7. System Events by Component Type
name=value pair Description
type=accords Reports events for AC power cords.
type=battery Reports events for batteries
type=fanenclosures
Reports events for fan enclosures.
type=fans Reports events for fans.
type=intrusion Reports events for chassis intrusion.
type=log Reports events for logs.
type=memory Reports events for memory.
type=powersupplies Reports events for power supplies.
type=redundancy Reports events for redundancy.