13 SCG1001 PowerConnect 8100 Series Configuration Guide
console(config-if-dcb)#exit
console(config-if)#exit
4.2 Revert to default VLAN ID on switch and arrays
Once DCB is disabled on the switch, the EqualLogic arrays will no longer use the VLAN ID that was
configured when DCB was enabled. The arrays will revert to the default or native VLAN. Therefore, a valid
VLAN must be configured for all host servers, switches, and EqualLogic array members. A valid VLAN can
use the default or native VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example,
VLAN 100). If a non-default VLAN is configured, then any ports connected to the arrays must be
configured as “untagged”.
Use the steps below to configure the native VLAN on the switch.
console#configure
console(config)#interface range tengigabitethernet all
console(config-if)#no switchport mode
console(conf-if)#exit
console(config)#interface range fortygigabitethernet all
console(config-if)#no switchport mode
console(config-if)#exit
console(config)#interface port-channel 1
console(config-if)#no switchport mode
console(config-if)#exit
console(config)#no vlan vlan-id
console(config)#exit
4.3 Save configuration
console# copy running-config startup-config
This operation may take a few minutes.
Management interfaces will not be available during this time.
Are you sure you want to save? (y/n)y