Page view 179
178 Using the Storage Management Service
Example Syntax
In this example, you want to blink physical disk 0 on connector 0 of controller 1.
On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To blink the physical disk described in this example, enter:
omconfig storage pdisk action=blink controller=1
pdisk=0:0
Example for SAS Controllers
To blink the physical disk described in this example, enter:
omconfig storage pdisk action=blink controller=1
pdisk=0:2:0
omconfig Unblink Physical Disk
You can unblink the light (light emitting diode or LED display) on one or
more physical disks attached to a controller. Use the following omconfig
command syntax to unblink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=unblink controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk.
To obtain these values, enter omreport storage controller to display the
controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to unblink physical disk 0 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To unblink the physical disk described in this example, enter:
omconfig storage pdisk action=unblink controller=1
pdisk=0:0
Page view 179