48 omreport: Viewing System Status Using the Instrumentation Service
External Socket Name Silk Screen Name is the name printed on the system
board next to the socket.
Error Correction Type identifies the type of error checking and correction
(ECC) that this memory can perform. Examples are correctable ECC or
uncorrectable ECC.
This report shows cache information for each cache present on the
microprocessor.
omreport chassis pwrmonitoring/omreport mainsystem pwrmonitoring
Use this omreport chassis pwrmonitoring or omreport mainsystem
pwrmonitoring command to view the properties of your system’s power
consumption. Type:
omreport chassis pwrmonitoring
or
omreport mainsystem pwrmonitoring
For each power monitoring in the system, values display for the following fields:
Power Consumption Status, Probe Name, Reading, Warning Threshold, and
Failure Threshold, Amperage: Location and Reading, Power Tracking
Statistics, Energy Consumption, Measurement Start Time, Measurement
Finish Time, Reading, System Peak Power, and System Peak Amperage.
NOTE: The omreport chassis pwrmonitoring or omreport mainsystem
pwrmonitoring command is applicable only to selected Dell xx0x systems that
support PMBus.
Power Consumption Information
Power Consumption
Index
Status
Probe Name
Reading
Warning Threshold
Failure Threshold
: 2
: Ok
: System Board System Level
: 539 W
: 994 W
: 1400 W