omconfig: Managing Components Using the Instrumentation Service 97
omconfig chassis pwrmonitoring config=probe index=
0 warnthresh=settodefault
or
omconfig mainsystem pwrmonitoring config=probe
index=0 warnthresh=settodefault
You cannot default one value and set another. If you default the minimum
warning threshold value, you are also selecting the default value for the
maximum warning threshold value.
Specify a Value for Warning Thresholds
If you prefer to specify values for the power consumption probe warning
thresholds, you must specify the number of the probe you are configuring and
the warning threshold value. You can configure the values to be displayed
either in BTU/hr or Watts. In the following example, the probe that is being
configured is probe 4:
omconfig chassis pwrmonitoring config=probe index=
4 warnthresh=325 unit=watt
or
omconfig mainsystem pwrmonitoring config=probe
index=4 warnthresh=325 unit=btuphr.
When you issue the command and the system sets the values you specify, the
following message appears:
Power consumption probe warning threshold(s) set
successfully.
omconfig chassis remoteaccess/omconfig mainsystem remoteaccess
NOTE: This command is applicable to PowerEdge x8xx, x9xx, xx0x, and xx1x
systems only.
Use the omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess command to configure:
Remote access on a local area network (LAN).
The serial port for BMC or RAC, whichever is installed.
The BMC or RAC on a serial over LAN connection.
Terminal settings for the serial port.