Figure 29. RIMM Removal
To reinstall a RIMM, perform the following steps:
1. Locate the plastic securing clips at each end of the socket (see Figure 30).
2. Press the clips outward until they snap open.
3. Press the RIMM straight into the slot running down the center of the socket until the securing tabs snap into place around the ends of the
RIMM.
4. Replace the computer cover and reset the chassis intrusion detector.
Figure 30. RIMM Installation
Microprocessor/Airflow Shroud/Heat Sink Assembly
To replace a microprocessor, perform the following steps:
1. Remove the computer cover.
2. Rotate the power supply up until it locks (see Figure 20).
3. Pull up on the airflow shroud release tabs while you lift and rotate the bottom of the shroud up and away from the back of the chassis and
microprocessor/heat sink assembly.
Figure 31. Microprocessor/Airflow Shroud/Heat Sink Removal
1
Securing clips (2)
1
Securing clips (2)
2
Notches (2)
CAUTION: The microprocessor SEC cartridge/heat sink assembly can get extremely hot. Be sure that the assembly has had
sufficient time to cool before you touch it.
NOTE: Dell recommends that only a technically knowledgeable person perform this procedure.