Dell PowerEdge R910 Owner's Manual Page 28

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 27
28 About Your System
E1313 Fan
redundancy
lost. Check
fans.
The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 180.
E1314 Critical
system
cooling loss.
Check fans.
All fans have been removed
from system.
Ensure that the fans are
properly installed. See
"Troubleshooting a Fan"
on page 180.
E1410 System Fatal
Error
detected.
A fatal system error has been
detected.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out of
acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processors" on page 190
and "Troubleshooting
System Cooling
Problems" on page 180.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processors" on page 190.
E141C Unsupported
CPU configur-
ation. Check
CPU or BIOS
revision.
Processors are in an
unsupported configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
Code Text Causes Corrective Actions
book.book Page 28 Wednesday, January 20, 2010 10:20 AM
Page view 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 209 210

Comments to this Manuals

No comments