Dell PowerEdge R910 Owner's Manual Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
About Your System 51
DellMemBIST
timeout: Memory
riser <x> DIMM
<y>
Memory riser <x>
lockstep pair
DIMM <x & y>
disabled.
Please replace
the DIMM(s) or
remove the
lockstep pair.
The memory modules are not
properly seated.
The memory module
connector may be exposed to
dust.
Faulty memory module.
Replace or reseat the
memory module(s). See
"Removing Memory
Modules" on page 105 and
"Installing Memory Modules"
on page 102.
Ensure that the memory
module connectors are clean.
DellMemBIST
error: Memory
riser <x> DIMM
<y>
Memory riser <x>
lockstep pair
DIMM <x & y>
disabled.
Please replace
the DIMM or
remove the
lockstep pair.
Manufacturing
mode detected.
System is in manufacturing
mode.
Reboot to take the system
out of manufacturing mode.
Memory address
line failure at
address
, read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page 181.
Memory double
word logic
failure at
address
, read
value
expecting
value.
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page 181.
Message Causes Corrective Actions
book.book Page 51 Wednesday, January 20, 2010 10:20 AM
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 209 210

Comments to this Manuals

No comments