Processor 1 internal error
Processor 2 internal error
Defective microprocessor or system board
(reported by the NMI handler).
Replace the specified microprocessor. See
"Microprocessors." If the problem persists, replace the
system board. See "System Board."
Processor 1 is a 533-MHz system bus processor
Processor 2 is a 533-MHz system bus processor
Two 533-MHz microprocessors are
installed. This system supports only
Intel®Xeon™400-MHz front-side-bus
processors.
Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace both processors
with Intel Xeon 400-MHz front-side-bus processors. See
"Microprocessors."
If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See Figure5-2 for jumper location.
Processor bus error
PCI bus error
IMB bus error
Defective system board (reported by the
NMI handler).
Replace the system board. See "System Board."
Processor x is not a 533-MHz system bus
processor
This system bus speed is not supported on this
system board
This system supports only Intel Xeon 533-
MHz front-side bus (system bus)
processors.
Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace processor x with
a supported processor. See "Microprocessors."
If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See Figure5-2 for jumper location.
Read fault
Requested sector not found
Faulty diskette, diskette-drive subsystem,
or hard-drive subsystem.
Replace the diskette. Reseat all drives and reboot the
system. If the message reappears, replace the diskette
drive. See "Installing a Diskette Drive." If the problem
persists, replace the system board. See "System Board."
Reset failed
Improperly connected diskette/tape drive,
hard drive, or power cable.
Check the drive and cable connections, and reset the
system again.
ROM bad checksum = address
Expansion card improperly installed or
faulty.
Reinstall the expansion card. See "Expansion Cards." If
the problem persists, replace the expansion card.
Sector not found
Seek error
Seek operation failed
Defective sectors on diskette or hard
drive.
Faulty diskette, diskette-drive subsystem,
or hard-drive subsystem.
Replace the diskette, or reseat all drives and reboot the
system. See "Installing a Diskette Drive" or "Internal SCSI
Hard Drives." If the message reappears, replace the drive
(s). If the problem persists, replace the system board.
See "System Board."
Shutdown failure
Defective system board.
Replace the system board. See "System Board."
System backplane error
Improperly attached or missing SCSI
backplane.
Reseat the SCSI backplane. See "SCSI Backplane Board."
System halted! Must power down.
Wrong password entered too many
times.
Reboot the system and enter the correct password. If the
problem persists, see "Disabling a Forgotten Password."
System parity error
Defective expansion card(s) or improperly
seated or faulty memory modules
(reported by the NMI handler).
Replace the expansion cards one at a time until the error
is corrected. See "Expansion Cards."
Remove and reseat the memory modules. See "Memory."
If the problem persists, replace the memory modules. If
the problem persists, replace the system board. See
"System Board."
The following memory DIMMs are unsupported:
DIMM_xx.
This system only supports 266 MHz DIMMs.
One or more of the installed DIMMs has a
frequency less than 266 MHz. System
memorymustberatedfor266MHz.
Replace lower-speed DIMM(s) with modules rated for 266-
MHz operation. See "Memory."
This processor system bus speed is unknown.
System halted!
The installed microprocessor is not
supported by the system.
Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace the installed
microprocessor(s) with microprocessor(s) supported by
your system. See "Microprocessors."
If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See Figure5-2 for jumper location.
This system only supports 400-MHz system bus
speed.
System halted!
Two 533-MHz microprocessors are
installed. This system supports only Intel
Xeon 400-MHz front-side-bus processors.
Reboot the system. If you receive beep code 4-4-3
(processor frequency mismatch), replace both processors
with Intel Xeon 400-MHz front-side-bus processors. See
"Microprocessors."
If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. See Figure5-2 for jumper location.
Time-of-day clock stopped
Defective battery or faulty chip (defective
system board).
Replace the system battery. See "System Battery." If the
problem persists, replace the system board. See "System
Board."
Time-of-day not set - please run SETUP program
Incorrect Time or Date settings or
defective system battery.
Check the Time and Date settings. See "Using the
System Setup Program." If the problem persists, replace
the system battery. See "System Battery." If the problem
persists, replace the system board. See "System Board."
Timer chip counter 2 failed
Defective system board.
Replace the system board. See "System Board."
Unsupported CPU combination
Microprocessor combination is not
supported by the system.
Install a supported microprocessor combination. See
"Microprocessors."
Unsupported CPU stepping detected.
Microprocessor is not supported by the
system.
Install the correct version of the microprocessor in the
specified microprocessor socket. See "Microprocessors."
Utility partition not available
<F10> key was pressed during POST, but
Create a utility partition on the boot hard drive. See