26 About Your System
Memory set to
minimum
frequency.
The memory frequency may
be intentionally set lower for
power conservation.
If not an intentional setting,
check any other system
messages for possible causes.
The current memory
configuration may support
only the minimum
frequency.
Ensure that your memory
configuration supports the
higher frequency. See
"General Memory Module
Installation Guidelines" on
page 79.
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure
detected on
x.
Invalid memory
configuration. A mismatched
memory module is installed.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 79.
No boot device
available.
Faulty or missing optical
drive subsystem, hard drive,
or hard-drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key, CD,
or hard drive. If the problem
persists, see
"Troubleshooting a USB
Device" on page 110,
"Troubleshooting an Optical
Drive" on page 119, and
"Troubleshooting a Hard
Drive" on page 120. See
"Using the System Setup
Program and UEFI Boot
Manager" on page 37 for
information on setting the
order of boot devices.
Message Causes Corrective Actions