Dell PowerEdge R905 Owner's Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 202
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
About Your System 35
CPUs with
different cache
sizes detected!
Microprocessors with
different cache sizes are
installed.
Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on
page 100.
Decreasing
available memory
Faulty or improperly
installed memory
modules.
See "Troubleshooting
System Memory" on
page 158.
Error: Incorrect
memory
configuration
CPU
n
The DIMM group for
CPU n is incorrectly
configured and caused
the system to halt.
See "General Memory
Module Installation
Guidelines" on page 94 for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.
!*** Error: Remote
Access Controller
initialization
failure *** RAC
virtual USB
devices may not be
available...
Remote Access Controller
initialization failure
Ensure that the Remote
Access Controller is
properly installed. See
"Installing an Optional
RAC Card" on page 86.
Gate A20 failure Faulty keyboard
controller; faulty system
board.
See "Getting Help" on
page 181.
General failure The operating system is
unable to carry out the
command.
This message is usually
followed by specific
information. Note the
information and take the
appropriate action to
resolve the problem.
Table 1-8. System Messages (continued)
Message Causes Corrective Actions
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 201 202

Comments to this Manuals

No comments