About Your System 25
E1414 CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling" on
page 138. If the problem
persists, ensure that the
processor heat sinks are
properly installed. See
"Troubleshooting
Processors" on page 147.
NOTE: The LCD continues
to display this message until
the system’s power cord is
disconnected and
reconnected to the AC
power source, or the SEL is
cleared using either Server
Assistant or the BMC
Management Utility. See the
Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these
utilities.
E1418 CPU #
Presence
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
See "Troubleshooting
Processors" on page 147.
E141C CPU
Mismatch
Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s
Getting
Started Guide
.
Table 1-5. LCD Status Messages