Dell OpenManage Server Administrator Version 5.5 User Manual Page 157

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 156
Using the Storage Management Service 155
[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional)
Different controllers support different write policies. Table 6-21 indicates
how to specify the [writepolicy=<wb| wt| wc| nwc | fwb>] parameter for
each of the write policies.
[name=<string>] Parameter (Optional)
Use this parameter to specify a name for the virtual disk. For example:
name=VirtualDisk1
NOTE: The CERC SATA 1.5/2s controller does not allow you to specify a virtual disk
name. The virtual disk will be created with a default name.
[spanlength=<n>] Parameter (Required for RAID 50 and RAID 60 and optional for
RAID 10)
Use this parameter to specify the number of physical disks to be included in
each stripe.
This parameter only applies to RAID-50 virtual disks. If you are
not creating a RAID-50 virtual disk, do not specify this parameter. For
example:
spanlength=3
For RAID 10 on SAS controllers with firmware version 6.1 and later,
spanlength is optional. Also, you can now specify the spanlength as an
even number with a maximum of 8 spans with 32 physical disks each. For
example,
omconfig storage controller action=createvdisk
controller=1 raid=r10 size=min pdisk=
1:1:0,1:1:1,1:1:3,1:1:4,1:1:6,1:1:7,1:1:8,1:1:9
spanlength=4
Table 6-21. Write Policy Parameters
Write Policy writepolicy=wb | wt | wc | fwb | nwc Parameter
Specification
Write–back cache writepolicy=wb
Write–through cache writepolicy=wt
Write cache writepolicy=wc
Force write back writepolicy=fwb
No write cache writepolicy=nwc
Page view 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 261 262

Comments to this Manuals

No comments