Dell OpenManage Server Administrator Version 6.0.1 User Manual Page 119

  • Download
  • Add to my manuals
  • Print
  • Page
    / 277
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 118
omconfig: Managing Components Using the Instrumentation Service 119
To clear the contents of the alert log, type:
omconfig system alertlog action=clear
or
omconfig servermodule alertlog action=clear
NOTE: Entering an invalid RAC user name may prevent the command log from
displaying. Clearing the command log resolves this condition.
To clear the contents of the command log, type:
omconfig system cmdlog action=clear
or
omconfig servermodule cmdlog action=clear
To clear the contents of the ESM log, type:
omconfig system esmlog action=clear
or
omconfig servermodule esmlog action=clear
omconfig system pedestinations/omconfig servermodule pedestinations
Use the omconfig system pedestinations or omconfig servermodule
pedestinations command to set IP addresses for alert destinations.
Table 4-23 shows the valid parameters for the command.
NOTE: You can either specify the index and IP address as parameters together or
you can set the only community string as a parameter.
Table 4-23. omconfig system pedestinations/omconfig servermodule pedestinations
name=Value Pair Description
destenable=true | false true: Enables an individual platform event filter destination after a
valid IP address has been set.
false: Disables an individual platform event filter.
index=number Sets the index for the destination.
ipaddress=ipv4|ipv6
address
Sets the IP address for the destination.
communitystr=text Sets the text string that acts as a password and is used to authenticate
SNMP messages sent between the BMC and the destination
management station.