omconfig: Managing Components Using the Instrumentation Service 89
You cannot default one value and set another. In other words, if you default
the minimum warning threshold value, you are also selecting the default
value for the maximum warning threshold value.
Specifying a Value for Minimum and Maximum Warning Thresholds
If you prefer to specify values for the fan probe warning thresholds, you must
specify the number of the probe you are configuring and the minimum and/or
maximum warning threshold values. In the following example, the probe that
is being configured is probe 0. The first command sets only the minimum
threshold; the second sets minimum and maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=
4580
omconfig chassis fans index=0 minwarnthresh=4580
maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=
4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the
following message appears:
Fan probe warning threshold(s) set successfully.
NOTE: Minimum and maximum warning thresholds for the fan probe cannot be set
on PowerEdge
x
8xx and x9xx systems.
omconfig chassis fancontrol/omconfig mainsystem fancontrol
Use the omconfig chassis fancontrol or omconfig mainsystem fancontrol
command to set the fan speed. You can optimize speed for cooling or for
quiet operation. Table 4-5 shows the valid parameters for the command.
Table 4-5. omconfig chassis fancontrol/omconfig mainsystem fancontrol
name=value pair Description
speed=quiet Sets fan speed for quiet operation.
speed=maxcool Sets fan speed for maximum cooling.