Dell PowerEdge R910 Owner's Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
About Your System 41
System Messages
System messages appear on the screen to notify you of a possible problem
with the system.
NOTE: If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Table 1-2. System Messages
W1630 Power supply
redundancy
degraded.
Check PSU
cables.
The power supply subsystem
is no longer fully redundant,
but at least one more supply
can fail before the system is
at risk of shutting down.
Reseat the power supplies.
See "Troubleshooting
Power Supplies" on
page 179.
If the problem persists,
see "Getting Help" on
page 203.
NOTE: For the full name of an abbreviation or acronym used in this table, see the
Glossary at support.dell.com/manuals.
Message Causes Corrective Actions
Alert! iDRAC6 not
responding.
Rebooting.
The iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization. The
system will reboot.
Wait for the system to
reboot.
Code Text Causes Corrective Actions
book.book Page 41 Wednesday, January 20, 2010 10:20 AM
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 209 210

Comments to this Manuals