Fabric OS v6.4.1 Release Notes v1.0 Page 19 of 62
Power Supply Requirements for B
Power Supply Requirements for BPower Supply Requirements for B
Power Supply Requirements for Blades in 48k and DCX/DCX
lades in 48k and DCX/DCXlades in 48k and DCX/DCX
lades in 48k and DCX/DCX-
--
-4S Chassis
4S Chassis4S Chassis
4S Chassis
Blades
BladesBlades
Blades
Type of
Type of Type of
Type of
Blade
BladeBlade
Blade
48K
48K48K
48K
@200-240
VAC
(Redundant
configurations)
DCX/DCX
DCX/DCXDCX/DCX
DCX/DCX
-
--
-
4S
4S4S
4S
@110 VAC
(Redundant
configurations)
DCX/DCX
DCX/DCXDCX/DCX
DCX/DCX
-
--
-
4S
4S4S
4S
@200-240 VAC
(Redundant
configurations)
Comments
CommentsComments
Comments
redundant
configuration with any
number of FS8-18
Blades.
For both DCX and
DCX-4S with FX8-24
blades, (1+1) 220VAC
Power Supplies are
required for
redundancy.
FOS Feature Compatibility in Native Connectivity Modes
FOS Feature Compatibility in Native Connectivity ModesFOS Feature Compatibility in Native Connectivity Modes
FOS Feature Compatibility in Native Connectivity Modes
Some FOS features are not fully supported when operating in the native connectivity modes for deployment
with M-EOS based products. All Brocade models that are supported by Fabric OS v6.4 support both
interopmodes 2 and 3 with the exception of the Brocade 4100 and 8000 and DCX/DCX-4S with one or more
FCOE10-24 blades.
The following table specifies the support of various FOS features when operating in either interopmode 2
(McDATA Fabric Mode) or interopmode 3 (Open Fabric Mode) with Fabric OS v6.4
.
FOS Features
FOS Features FOS Features
FOS Features
(supported in interopmode 0)
FOS v6.4
FOS v6.4FOS v6.4
FOS v6.4
IM = Interopmode
IM = InteropmodeIM = Interopmode
IM = Interopmode
IM 2
IM 2IM 2
IM 2
IM 3
IM 3IM 3
IM 3
L2 FOS Hot Code Load
Yes
Yes
FOS Hot
Code Load with FCR
Yes
Yes
Zone Activation Support
Yes
Yes
11
Traffic Isolation Zones
1
Yes
No
Frame Redirection (devices attached to FOS)
1
Yes
Yes
11
Frame Redirection (devices attached to M
-
EOS)
1
Yes
Yes
11
Frame Redirection over FCR
10
Yes
Yes
11
FCR
Fabric Binding (route to M
-
EOS fabric with Fabric binding)
9
Yes
Yes
L2 Fabric Binding
Yes
No*
DCC policies
No
No
SCC policies
Yes
4
No*
E/EX_Port Authentication
Yes
Yes
ISL Trunking (frame
-
level)
Yes
2
Yes
2
Dynamic Path Selection (DPS, exchange based
routing)
Yes
3
Yes
3
Dynamic Load Sharing (DLS, port based routing)
Yes
Yes
Virtual Channels (VC RDY)
Yes
2
Yes
2
FICON Management Server (Cascading)
Yes
No*
FICON MIHPTO
Yes
No*
Full Scalability (to maximum M
-
EOS fabric limits)
Yes
Yes
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 61 62

Comments to this Manuals