Dell VA-40FC Service Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
Close with Code Change in Fabric OS v6.4.1
Fabric OS v6.4.1 Release Notes v1.0 Page 41 of 62
Defect ID: DEFECT000274403 Technical Severity: Medium
Summary: One directional route problem in fabric prevents local switch communicating to remote
switch, causing remote switch to disable local switch without any notification.
Symptom: Switch goes to disabled state without any reason logged, and with no user action.
Customer sees messages indicating RTWR has reached max retries in RASLOG.
Feature: Field Escalation Function: RAS Logging / Tracing
Probability: Low
Found in Release: FOS6.2.0 Service Request ID: 411755
Defect ID: DEFECT000282759 Technical Severity: Medium
Summary: Switches in AG mode are not handling multi-sequence frames properly. This causes
memory corruption and switch panic.
Symptom: One or more switches in AG mode in the same fabric have an agdd panic occur. RASLOG
error messages like: "[KSWD-1002], 1285, FFDC | CHASSIS, WARNING, Brocade300,
Detected termination of process agd0:1793" are seen and then debug information is
dumped.
Feature: Field Escalation Function: Access Gateway
Probability: Low
Found in Release: FOS6.3.0 Service Request ID: 419851
Defect ID: DEFECT000286898 Technical Severity: Medium
Summary: Switch panics after information unit (iu) allocation failure.
Symptom: When a frame comes in to the embedded port and there is no memory to hold it
temporarily, the switch panics. This is likely to happen when there are spurious interrupts
from a device. It impacts 4G switches only.
Feature: Field Escalation Function: ASIC Driver
Probability: Low
Found in Release: FOS6.1.0 Service Request ID: 423799
Where Else Fixed: FOS6.3.2
Defect ID: DEFECT000287990 Technical Severity: Medium
Summary: Value of 0xffffffff in the config file for the N_Port topology field causes an error and fails the
configdownload operation.
Symptom: Using the configdownload command on a BES in AG mode with SRDF enabled fails with the
following error: strtoul failed str 0xffffffff, errno =2 aglib_strtobm failed for
ag.pg.pgporttopo.0 value = 0xffffffff configDownload: agImport() failed key = ag.pg.pgp
Feature: Access Gateway Services Function: Other
Probability: Medium
Found in Release: FOS6.4.0
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 61 62

Comments to this Manuals

No comments