Closed with Code Change in Fabric OS v6.4.0c - GA September 2, 2010
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change
as of September 2, 2010 in Fabric OS v6.4.0c.
Defect ID: DEFECT000301286 Technical Severity: High
Summary: Routes are not properly redistributed after trunk group loses a trunk member.
Symptom: In a setup with 8G switches running exchanged base route policy, the routes are not
rebalanced properly after a trunk group loses a member. This may cause performance to
be sluggish on 8G switches fabric if there happens to be a slow drain device using the
lower bandwidth links to further congest the fabric. This only impacts 8G switches.
Workaround: Keep trunk groups with equal bandwidth.
Feature: Field Escalation
Function: FC Layer 2 Routing
Probability: Medium
Found in Release: FOS6.2.1
Service Request ID: 433171
Where Else Fixed:
FOS6.3.2
Defect ID: DEFECT000310231 Technical Severity: High
Summary: Constant link resets occur when a long distance port is configured.
Symptom: After configuring a long distance E_Port that requires 128 to 511 credits the customer
observes continuously link timeout with no traffic running. Constant stream of C2-5021.
This, only, affects 8G platforms.
Workaround: Use QOS mode
Feature: Field Escalation
Function: ASIC Driver
Probability: Medium
Found in Release: FOS6.3.1
Service Request ID: 443673
Defect ID: DEFECT000315258 Technical Severity: High
Summary: Switch panics, blade faults, or switch is disabled when credit loss is detected on backend
link.
Symptom: When credit loss happens on internal backend port, RASLOG C-5021 or C2-5021 is
reported with “S#,P-1(#)”. If this happens on:
• FR4-18i: Blade is faulted.
• Brocade 4900,5300 and7500: Switch is faulted/disabled.
• All other switches/directors: hareboot/hafailover will eventually happen.
An example of C2-5021 internal port raslog as: [C2-5021], 730078/0, SLOT 6 | CHASSIS,
WARNING, , S8,P-1(61): Link Timeout,….
Feature: 8G Platform Services
Function: FOS Kernel Drivers
Probability: Low
Found in Release: FOS6.4.0