Using the Storage Management Service 169
concatenated non-redundant virtual disks. Splitting a RAID-10 mirror creates
two RAID-0 (striped) non-redundant virtual disks. Data is not lost during this
operation.
Complete Syntax
omconfig storage vdisk action=splitmirror
controller=id vdisk=id
where id is the controller ID and virtual disk ID as reported by the omreport
command. To obtain these values, enter omreport storage controller to
display the controller IDs and then enter omreport storage vdisk controller=ID
to display the IDs for the virtual disks attached to the controller.
Example Syntax
To initiate a split mirror on virtual disk 4 on controller 1, enter:
omconfig storage vdisk action=splitmirror
controller=1 vdisk=4
omconfig Unmirror
Use the following omconfig command syntax to separate mirrored data and
restore one half of the mirror to free space. Unmirroring a RAID-1 or
RAID-1–concatenated virtual disk results in a single, non-redundant
concatenated virtual disk. Unmirroring a RAID-10 virtual disk results in a
single, non-redundant RAID-0 (striped) virtual disk. Data is not lost during
this operation. See the Dell OpenManage Online Help for more information
about Unmirror.
Complete Syntax
omconfig storage vdisk action=unmirror controller=
id vdisk=id
where id is the controller ID and virtual disk ID as reported by the omreport
command. To obtain these values, enter omreport storage controller to
display the controller IDs and then enter omreport storage vdisk controller=ID
to display the IDs for the virtual disks attached to the controller.