Dell OpenManage Server Administrator Version 5.5 User Manual Page 186

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 185
184 Using the Storage Management Service
Complete Syntax
omconfig storage pdisk action=assignglobalhotspare
controller=id pdisk=<PDISKID> assign=no
where id is the controller ID. The <PDISK> variable specifies the physical disk.
To obtain these values, enter omreport storage controller to display the
controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to unassign physical disk 3 on connector 0 of
controller 1 as a global hot spare. On a SAS controller, the physical disk
resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To unassign the physical disk described in this example as a global hot spare,
enter:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:3 assign=no
Example for SAS Controllers
To unassign the physical disk described in this example as a global hot spare,
enter:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:2:3 assign=no
omconfig Rebuild Physical Disk
Use the following omconfig command syntax to rebuild a failed physical disk.
Rebuilding a disk may take several hours. If you need to cancel the rebuild,
use the Cancel Rebuild task. See the Dell OpenManage Online Help for more
information about Rebuild Physical Disk.
Page view 185
1 2 ... 181 182 183 184 185 186 187 188 189 190 191 ... 261 262

Comments to this Manuals

No comments