Dell OpenManage Server Administrator Version 5.5 User Manual Page 96

  • Download
  • Add to my manuals
  • Print
  • Page
    / 262
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 95
96 omconfig: Managing Components Using the Instrumentation Service
omconfig chassis temps/omconfig mainsystem temps
Use the omconfig chassis temps or omconfig mainsystem temps command
to set warning thresholds for temperature probes. As with other components,
you can view both warning and failure threshold values, but you cannot set
failure threshold values. Your system's manufacturer sets the minimum and
maximum failure threshold values.
NOTE: Threshold values that you can set vary from one system configuration
to another.
Valid Parameters for Temperature Warning Thresholds
Table 4-14 shows the valid parameters for setting temperature warning
thresholds:
Table 4-13. omconfig chassis remoteaccess config=user id=<user id>
extimpiusergroup=custom/omconfig mainsystem remoteaccess config=
user id=<user id> extimpiusergroup=custom
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user
(continued)
id=user id
extimpiusergroup=custom
NOTE: extimpiusergroup
user group is available only on
Dell xx0x modular systems.
loginidrac= true |
false
configureidrac= true
| false
true/false:
Enables/disables logging
into iDRAC.
true/false:
Enables/disables
configuration of
iDRAC.
Table 4-14. omconfig chassis temps/omconfig mainsystem temps
name=value pair Description
index=<n> Number of the probe or probe index (must be specified).
warnthresh=default Sets the minimum and maximum warning threshold values to
default.
minwarnthresh=<n> Sets the minimum warning threshold values (1 decimal place).
maxwarnthresh=<n> Sets the maximum warning threshold values (1 decimal place).
Page view 95