Dell VA-40FC Service Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 62
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
Close with Code Change in Fabric OS v6.4.0b
Fabric OS v6.4.1 Release Notes v1.0 Page 53 of 62
Defect ID: DEFECT000270825 Technical Severity: Medium
Summary: Expose all 64 bit port stats counter through SNMP
Symptom: 64 bit port stats is only available in CLI via portStats64Show, it's not exposed through
SNMP.
Feature: Mgmt Embedded - SNMP
Function: Other
Probability: Low
Found in Release: FOS6.4.0
Defect ID: DEFECT000273725 Technical Severity: Medium
Summary: Detected termination of webd and triggered call home event.
Symptom: At a customer site, webd terminated and restarted from time to time. At the same time as
the webd crash, HA status temporarily went to non-redundant, which triggered a Call Home
event. webd was killed by watchdog as webd was waiting for a reply from a busy httpd and
webd did not have a timeout mechanism. No other functional impact observed besides call
home event.
Feature: Field Escalation
Function: Management Services
Probability: Low
Found in Release: FOS6.2.0
Service Request ID: 412187
Defect ID: DEFECT000286033 Technical Severity: Medium
Summary: Bottleneckmon cannot be enabled on F-ports with "Locked G_Port" AND "Disabled E_Port"
enabled in portcfg.
Symptom: Customer is not able to enable bottleneckmon --enable <port> on switches with message
"Error: port is not an F_Port". The command works as expected after disable Locked G_Port
option. This error happens only when both "Locked G_Port " AND "Disabled E_Port"
parameters are "on" in portcfgshow.
Workaround: Disable either or both "Locked G_Port " AND "Disabled E_Port" features; However,
changing these features is disruptive.
Feature: Field Escalation
Function: OS: Configuration
Probability: High
Found in Release: FOS6.3.1
Service Request ID: 423357
Defect ID: DEFECT000298078 Technical Severity: Medium
Summary: Backup to all cleartext containers using tape application (Netbackup) in a multiplex/stream
environment results in a Brocade Encryption Switch fault
Symptom: The system will fault and result in tape flows halting.
Feature: Data Security
Function: Tape Encryption
Probability: Medium
Found in Release: FOS6.3.0
Service Request ID: 429393