Dell PowerEdge R910 Owner's Manual Page 55

  • Download
  • Add to my manuals
  • Print
  • Page
    / 210
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 54
About Your System 55
SATA port
x
device auto-
sensing error
SATA port
x
device
configuration
error.
SATA port
x
device error
The drive connected to the
specified SATA port is faulty.
Replace the faulty drive.
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 174 or
"Troubleshooting a Hard
Drive" on page 186 for the
appropriate drive(s) installed
in your system.
Shutdown failure General system error. See "Getting Help" on
page 203.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting System
Memory" on page 181.
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 178.
Message Causes Corrective Actions
book.book Page 55 Wednesday, January 20, 2010 10:20 AM
Page view 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 209 210

Comments to this Manuals

No comments