S60 Specifications | 32
DC Power Requirements
IEEE Standards
The S60 complies with the following IEEE standards:
802.3ae 10 Gigabit Ethernet
802.3ab 1000Base-T
802.1p L2 Prioritization
802.1Q VLAN Tagging, Double VLAN Tagging (Q in Q), GVRP
802.1s Multiple Spanning Tree Protocol
802.1w Rapid Spanning Tree Protocol
802.3ad Link Aggregation with LACP
802.1D Bridging, GARP, GMRP
802.3x Flow Control
802.1ac Frame Extension for VLAN tagging
802.1x Port based Network Access Control
Agency Compliance
The S60 system is designed to comply with the following safety and agency requirements.
Network Equipment Building Systems (NEBS) Compliance
Use shielded cables for ports 0 - 43. The shields must be grounded at both ends.
You can only use reverse airflow configurations in a NEBS-compliant installation. Use only supported
Dell S60 AC power supply units, DC power supply units, and fans.
You must fit the Power Supply Units (PSUs) and fan modules with the supported Dell S60 filter kits.
You must replace the fan filters on a regular basis.
Use this equipment with an external second-level 6kV lightning Surge Protection Device (SPD) at the
AC input of the building.
For the NEBS-compliant installation, in order to protect the AC PSUs from damage due to excessive
power line surges, AC power connections must use a SPD.
In order to comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power
Ports, use an external SPD at the AC input of the router.
Parameter Specifications
Nominal input voltage –40 to – 60 VDC
Maximum power supply input current 3.6 A at -48 VDC
Maximum system power input 225 W